Tuesday, 21 August 2018 13:48

Recirculating Chillers

Written by

Laboratory Chillers

Labplant are independant distributors of Laboratory Chillers in the UK.

FL300 Recirculating Cooler / Chiller

For environmentally friendly cooling.

The JULABO FL series offers a new generation of chillers for routine cooling applications within the laboratory and industry. The working temperature range covers –20°C to +40°C, the temperature stability of the PID control is ±0.5°C.

All units can easily be cleaned and are provided with a splash water proof keypad with LED temperature indication. On the front of the units there is an RS232 interface as well as an alarm shutdown. The filling port is easily accessible placed on the top under a lift-up cover. Another hinged tray serves as a file for the operating manual or other documents concerning the installation. The removable venting grid allows an easy cleaning of the condenser, the drain tap is easily acceable behind the grid. All models include an easily visible level indication. Another advantage is the venting slots are on the front and rear and therefore the units can be placed directly one beside the other (space saving).

 

 

XT5718LT Refrigerated Circulator

Product Information:

  • Blue TickPatented stepper valve hot gas by-passing and dynamic temperature control for stability up to ± 0.1 °C, for continuous reliable operation
  • Blue TickAvailable with cooling capacity for 400 W, 800 W, 1,200 W, 1,600 W and 2,000 W
  • Blue TickMagnetic driven pump for quiet but powerful circulating, seamless liquid delivery and precise temperature control

 

 

F250 Recirculating Cooler / EcoChiller

A compact design for simple cooling tasks

JULABO F models require very little space and have very low procurement costs. Recirculating coolers of the F Series are a great way to replace costly tap water and are ideal for basic cooling tasks.

Your Advantages

  • Blue TickEnvironmentally-friendly operation with low energy consumption
  • Blue TickSplash-proof membrane keypad with LED temperature display
  • Blue TickStraightforward filling and drainingwith filling level indicator
  • Blue TickMay be used with water, water/glycol, JULABO Thermal G

Chillers

julabo fl300

xtemp 5718

 

julabo fl300 2

 get a quote button

Tuesday, 21 August 2018 13:40

Reactors & Distillation

Written by

Reactors & Distillation

The SD-06 spray dryer is the perfect all in one research solution, the smallest foot print of any comparable spray dryer on the market and is the easiest of any spray dryer to setup and use by a single operator. The accessories available and the customisability of our units offer the user a multitude of spray drying options and ways to control the operation, giving the best product yield in the industry.

get a quote button

The SD06 has a chemical resistant stainless steel cabinet.

spray dryer sd 06

 

A 2 channel nozzle incorporates an automatic de-blocking device

spray dryer 2 channel nozzle

 

A clear LED screen ensures that all functions are easy to use

spray dryer sd06 closeup

 

get a quote button

Tuesday, 21 August 2018 13:16

Flash Point Tester

Written by

Automated Flash Point Closed Cup Tester

The NPM 450 is the 5th generation of the automated flash point tester developed by Normalab

Standards

ASTM D93, IP 34, NFM 07019, ISO 2719, DIN 51758, GBT 261, JIS K2265-3

Scope

These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 to 360°C and biodiesel from 60 to 190°C by manual or automated Pensky-Martens closed cup apparatus.

MAIN CHARACTERISTICS

  • Blue TickTest temperature range: 0 to 410°C
  • Blue TickFlash point detection by thermocouple
  • Blue TickElectric and gas ignition (unique combined system)
  • Blue TickRegulated electric ignitor Automatic gas flame relighting
  • Blue TickIntegrated barometric correction
  • Blue TickOne hand easy operation
  • Blue Tick6.4 inch high definition screen
  • Blue TickCapacitive touch screen (gloves usable)
  • Blue TickStandard methods: A, B, C
  • Blue TickUser programmable methods
  • Blue TickPredictive heating regulation
  • Blue TickHeavy sample preheating and automatic stirring start
  • Blue TickFast heating and cooling
  • Blue TickSample cup, probe, thermocouple holder stand
  • Blue TickSmall size

Unit Operation

The NPM 450 Automated Flash Point Closed Cup Tester is operable through an integrated touchscreen and Windows8® based software.

Dimensions

(W) 260 x (D) 460 x (H) 185 mm  ± 12 kg

closed cup flash point tester 01

Efficient & Compact Unit

 

closed cup flash point tester 02

Stirring & Dipping Arm

 

closed cup flash point tester 03

Unique Gas & Electric System

 

get a quote button

Tuesday, 21 August 2018 13:14

Orbis STARDist

Written by

Orbis STARDist - Automatic Distillation Unit

STARDist is our brand new Automatic Distillation Unit and includes new and innovative features such as Optical Dry Point Detection, Voc Cold Trap, HD Volume Scan, Automatic Heater Lift, Smart Heater Control and much more.

Methods: ASTM D86, D1078, D850, EN ISO 3405, IP123, JIS K2254, and other related methods

PreScan

The sample temperature and exact percentage of volume are measured by the Volume Scan before the start of each test. Receiving chamber temperature is then automatically set to sample temperature to eliminate incorrect volume measurement due to thermal expansion. Subsequently, the actual measured volume is corrected to 100% volume.

Flask installer

The simple and elegant flask holder design ensures easy and correct positioning of the distillation flask for both 125 ml and 200 ml flasks.

Moreover it ensures that the probe‘s height in relation to the flask’s side arm is always correct.

Optical Dry Sense

This unique built-in feature for Dry Point Detection eliminates the need for an external dry point sensor. It ensures higher accuracy and easier handling while keeping operating costs low.

Especially suitable for tests in which dry point detection is required (tests according to ASTM D850 & D1078, but also D86 and other related methods).

Voc Cold Trap

Designed to minimize evaporation loss of volatile organic compounds, this unique built-in feature ensures safer surroundings while improving the accuracy and repeatability of distillation results.

HD Volume Scan

The second generation Volume Scan is equipped with a HD CCD camera that provides two times the precision and accuracy of its predecessor in the former PAMv2 distillation unit. Includes Peltier controlled temperature regulation.

Advanced Heat Control

Early-on detection of the distillation behavior and smart internal algorithms enable real-time accurate heater control.

This results in increased IBP/FBP repeatability, “right-in-time” IBP detection and a distillation rate kept smoothly between 4 - 5 ml per minute, even with complicated blends such as 20% ethanol-in-gasoline.

Automatic final heat is automatically optimized for any type of sample, even for “heavy tail” samples.

Software app

Simple screens and logical navigation structure give users quick access to basic functions such as “choose program”, “start test”, “monitor distillation” and “view results”.

Custom distillation points, such as volume at 250ºC, can be added to the test results even after the test is finished.

Password protected access allows experienced users to customize program settings and manage menus for connection to LIMS and Windows PC, printing, calibration and more.

Storage on built-in iPad: 20.000 results, 1.000 programs and 100 users.

Fast Heater Cooling

2 adjustable and powerful fans ensure quick heater and flask cooling after the test is finished.

Fire Detection

Sensitive UV fire detection sensor and connection to N / CO2 for built-in fire extinguisher.

Built-in Drop Deflector

Increases ease of use and reduces operator mistakes from misplacing or forgetting to insert drop deflector.

Automatic Distillation Unit 01

 

Automatic Distillation Unit 02

 

Automatic Distillation Unit 03

 

get a quote button

Tuesday, 21 August 2018 13:14

Orbis CFPP & CPPP

Written by

AirSTAR CFPP (Cold Filter Plugging Point) Analyser

The standalone, fully automatic AirSTAR CFPP is our brand new instrument for Cold Filter Plugging Point Testing.

While fully compliant with conventional CFPP methods and equipped with all control options that are also present in similar instruments, AirSTAR CFPP offers today’s latest and most innovative technology such as NANOtech insulation, microprocessor controlled vacuum pump, solid state liquid-free cooling engine, wireless power and wireless control.

With integrated, solid state cooling down to -105ºC/-157ºF, a bench space of only 15cm/5,9″ (the width of the integrated iPad Mini), the innovative & easy hand-held CFPP module and a no-cables-no-hoses configuration, AirSTAR CFPP offers customers an instrument that is powerful, easy to use, flexible and future-proof. And, of course, with highly accurate and comparable test results.

Operation is easy and fast with the wireless hand-held CFPP module, in which all necessary components for the CFPP test are encaged. The intuitive software on the iPad Mini ensures a short learning curve for operators, so they’re able to create and customize programs and settings quickly. Multiple users and user acces levels can be created by the administrator.

Automatic cleaning is done when the CFPP pod is placed in either the ColdBlock cooling bath or the external cleaning station.

The iPad Mini can control up to 8 CFPP pods simultaneously, which gives customers the flexibility to make any combination of multiple ColdBlock cooling baths, multiple cleaning stations and CFPP pods. With this modular approach a customer’s investment in AirSTAR is always future proof.

Modern, versatile data handling option such as; send to LIMS / Windows PC, make PDF, send email, multiple printing options and more, enable AirSTAR CFPP to fit in flexibly in any existent data workflow.

AirSTAR CPPP Analyzer

The AirSTAR CPPP software application is designed for easy & flexible control. It offers extensive options for data recording and display, and many options to customize programs. Test results and progress animation are displayed real-time.

Cooling

The ColdBlock integrated cooling unit is friendly to environment, people and maintenance department. With the capacity to cool down to -105ºC, no external chillers are required. ColdBlock is completely liquid-free.

Concept

AirSTAR CPPP is modular: ColdBlock and CPPP Head are modules that can be combined and used independently from one another. Imagine for instance two ColdBlocks and three CPPP Heads, where one Head is always clean and ready for start on either one of the two ColdBlocks.

Innovation

AirSTAR CPPP is full of innovative technology that makes CPPP testing easier, faster, and more reliable. One example is the cable-free design. Users simply take out the CPPP Head from the ColdBlock and put it in the optional Docking station, and vice versa. All without having to (dis)connect any cables or hoses.

Results

AirSTAR CPPP strictly conforms to applicable ASTM, EN, IP and JIS methods, and results are reliable and precise. Results are stored on the iPad and printed on almost any printer. Other options: connect to Windows PC, send to LIMS and/or email results directly from the iPad.

CPPP Head features

  • tick One Head for both cloud point and pour point testing
  • tick High resolution camera for accurate detection of cloud point and pour point
  • tick Integrated microprocessor-controlled mechanism for lifting and tilting the jar
  • tick Powercast® technology for wireless power to CPPP Head
  • tick PT-100 with easy click-connection, built-in storage for calibration data & unique ID
  • tick Easy assembling
  • tick Create linear and stepped cooling profiles
  • tick Simultaneous CP and PP testing possible
  • tick Programmable warm-up of cooling bath before and after test
  • tick Specify end-test conditions in program
  • tick Monitor and record sample cooling rate data
  • tick Define “Start at” temperature for each test
  • tick Multiple users with variable access rights can be created by the administrator
  • tick Connect multiple CPPP Heads to one ColdBlock

airstar cfpp tester logo

Cold Filter Plugging Point Tester 01

 

Cold Filter Plugging Point Tester 02

 

Cold Filter Plugging Point Tester 03

 

Cold Filter Plugging Point Tester 04

 

get a quote button

Labplant UK Product Servicing

We offer a wide range of services supported by well trained and experienced staff using today's technology.

The following provides a guide to the range of services and only represents a cross section of those covered.

We provide a centralised, co-ordinated approach to calibration management operated by a single team employing a PC database for scheduling work with a 48 hour response equipment repair service.

Calibration and service certificates are supplied, which are traceable to national standards.

Service reports are supplied detailing faults found and rectified.

Calibration certificates can be supplied after repair.

Method development service or assistance and problem solving services for analytical equipment and/or methodology along with training in many aspects of analysis and calibration make us a one-stop shop for your servicing.

 

get a quote button

product servicing 2

 

product servicing 1

Monday, 20 August 2018 08:49

Incubators

Written by

Incubators

The E Series sizes are 65L, 151L and 205L with a temperature range ambient 3°C to 60°C. Film heaters located externally on the chamber sides makes the unit completely vibration free.The G Series sizes are 60L, 102L and 151L with a temperature range ambient 5°C to 70°C. The chamber is air jacketed and uses convection heating. The G Series also comes with Labtracer software to both control and data log the unit via PC.

Incubated Shaker - Benchtop Type

Digital incubating/ refrigerating benchtop shakers.

Combines a benchtop incubator, refrigerator with dual-action in orbital and reciprocating shakers.

Fulfills a variety of molecular biology, general incubation, and cell culture applications.

Economy Incubator

Space saving design and dependable, trouble-free heating system.

IB-E series completely warp inner chambers in film type heaters that is perfectly safe from any mechanical vibration and noise, in addition to prevents frequent mechanical trouble.

 

si 600r shaker

economy incubator

 

get a quote button

Monday, 20 August 2018 08:49

Laboratory Ovens

Written by

Laboratory Ovens

Laboratory ovens are ovens for high-forced volume thermal convection applications. These ovens generally provide uniform temperatures throughout.

Process applications for laboratory ovens can be for annealing, die-bond curing, drying, Polyimide baking, sterilizing, and other industrial laboratory functions. 

Typical sizes are from one cubic foot to 0.9 cubic metres (32 cu ft) with temperatures that can be over 340 degrees Celsius.

Laboratory ovens can be used in numerous different applications and configurations, including clean rooms, forced convection, horizontal airflow, inert atmosphere, natural convection, and pass through.

Some of the types of industries that typically use these laboratory ovens are the healthcare industry, technology industry, and transportation industry.

Civil engineering laboratories uses ovens for drying asphalt, soil, rock, or concrete samples

Vacuum Ovens

Optimal vacuum ovens with wide temperature range for various test applications.

The OV series is ideal for separating a solvent from a solution without high temperature drying on a phase of the substance containing humidity or other solvents. Also, for drying solvents with high boiling points because vacuum conditions makes the boiling points become low, which dry solvents easily.

Forced Convection Ovens

Intensive drying performance with a powerful air-flow. The OF-G series has a quiet and powerful air-flow for high air exchange rates and short rise times that guarantee intensive drying performance, especially for material with high moisture content.

Laboratory vaccuum oven

Laboratory Vaccuum Oven

Forced Convection Oven

Forced Convection Oven

get a quote button

Monday, 20 August 2018 08:49

Laboratory Baths & Circulators

Written by

Viscometer Heating Bath

Ultra precise temperature control with excellent visibility!

VB-G series maintains temperatures ±0.05°C between ambient +5°C and 150°C.

Operating features

  • Blue TickAbove room temperature to 150°C
  • Blue TickMicroprocess PID control/ Auto-tuning/ Calibration
  • Blue TickDigital timer: 1 min to 99 hr 59 min, delayed ON/ OFF
  • Blue TickOver-temperature limiter and low fluid level protection
  • Blue Tick3 different temperature values memorable without auto-tuning
  • Blue TickDigital LED display with splash-proof keypads
  • Blue Tick(0.01°C resolution at 0 99.9°C)
  • Blue Tick0.1°C resolution at 100 - 150°C)
  • Blue TickRS-232 interface available

Click here for full range of baths and circulators

Viscometer Heating Bath

Viscometer Heating Bath

 

get a quote button

Monday, 20 August 2018 08:48

Lovibond Colorimeter

Written by

Product Servicing

The SD-06 spray dryer is the perfect all in one research solution, the smallest foot print of any comparable spray dryer on the market and is the easiest of any spray dryer to setup and use by a single operator. The accessories available and the customisability of our units offer the user a multitude of spray drying options and ways to control the operation, giving the best product yield in the industry.

The SD 06 Spray Dryer is the perfect all in one research solution.

  • Blue TickEfficient, touch screen-controlled spray drying of temperature sensitive products.
  • Blue TickAqueous only (A Version), Aqueous and solvent (AG Version) based solutions.
  • Blue TickAll in one solution, quick assembly and ease of use by a single operator.
  • Blue TickDesigned specifically for research and pre-production trials.
  • Blue TickEasily adaptable for dual cyclone high yield use.
  • Blue TickWide range of customizable spares and accessories.
  • Blue TickSpray dryer fittings.

Construction

A robust chemically resistant 316 grade stainless steel cabinet houses all mechanical and electrical components. All clamps and fittings are designed to allow efficient assembly and removal of the glassware. The rear of the cabinet includes an inlet filter designed to remove 99.99% of air laden particles ensuring that the drying air does not include contaminants. A specially designed stainless-steel support stand is available where bench space or height restrictions are a consideration.

Two Channel Nozzle

The 316 stainless steel atomiser consists of an inner tube for the liquid sample leading to a small diameter jet. An outer tube directs the supply of compressed air to the nozzle and the close tolerance gap between the nozzle and the jet ensures a fine vaporized spray. The SD-06 is supplied as standard with 0.5 mm jet, other sizes are available as accessories. The atomiser incorporates an automatic de-blocking device that prevents the jet nozzle from becoming blocked, this is activated by an integral compressor. De-blocking is sometimes necessary with materials which may solidify or when large particles in suspension cause blockages in the jet.

Spray Dryer Control Controls & Functionality

The SD-06 Spray Drier is designed to ensure that all functions are simple to select and adjust to quickly achieve the optimum conditions for spray drying. Using a clear touch screen and LCD display which is protected to IP65, the operator can control the following functions.

  • Blue TickInlet temperature
  • Blue TickAirflow Volume
  • Blue TickPump speed
  • Blue TickDe-blocker frequency
  • Blue TickTemperature Graph

get a quote button

The SD06 has a chemical resistant stainless steel cabinet.

spray dryer sd 06

 

A 2 channel nozzle incorporates an automatic de-blocking device

spray dryer 2 channel nozzle

 

A clear LED screen ensures that all functions are easy to use

spray dryer sd06 closeup

 

get a quote button

Page 4 of 5
×