Sales: 44 (0) 1723 892262

Cannon® CCS-2100 Cold Cranking Simulator

  • Cooled by Built-in Solid-State Thermoelectric Modules
  • Powerful VISCPRO® for Windows® Software
  • Fully Automatic Operation
  • Improved Precision Over Earlier Models
CANNON CCS-2100 Cold Cranking Simulator

CANNON Thermoelectrically-Cooled Cold-Cranking Simulators measure the apparent viscosity of oils at temperatures from –35°C to –5°C within a viscosity range of 1500 mPa·s to 27,000 mPa·s.

The CCS-2100 combines automatic sample loading, computer-controlled operation, and solvent-free cleaning to permit completely unattended operation. No further operator involvement is required after initial loading of the sample table and identification of samples.

The CCS-2100 will automatically test up to 30 samples at one time, calculate their viscosities, and record the results, freeing the operator for other tasks. Improved temperature management of the rotor/stator eliminates the need for grouping the samples by temperature of analysis, as was necessary in older CCS models.

In addition, a thermoelectric sample warming cycle greatly improves the sample flushing process.

The CCS-2100 meets all the requirements of ASTM D 5293 and SAE J300.

The CCS-2100 consists of a patented thermoelectrically-cooled rotor/stator, a Sample Table with capacity for 30 oil samples, and an integral CCS Series II Controller. The rotor/stator cell is attached to a vacuum system and a metering constant-displacement injection pump. The rotor/stator cell is cleaned by purging the previously measured sample with a portion of new sample prior to measuring its viscosity. Purged sample is drawn into a waste receiver by the vacuum system. Rotor speed is measured by a high resolution digital encoder. A proprietary software program then converts this data to sample viscosity. Viscosity calculations are based on test data and rotor/stator calibration information stored by the software.

User interface options include an instrument calibration routine, configuration of test cycles, and multiple means of processing test data including save, print, and export via the RS-232 serial port for LIMS capture.

First Name
required
Last Name
required
Email
required
Telephone
 
Enquiry
 
Allow contact by email
 

Call for current price

Cannon® CCS-2100 Cold Cranking Simulator
Technical data
Dimensions (W x D x H)
(add 100 mm depth for installation)
333 x 645 x 711 mm
Weight
46 kg
Shipping weight
136 kg
Electrical - CCS-2100
115 VAC ±10%
60 Hz
1000 W
Electrical - CCS-2100F
230 VAC ±10%
50 Hz
1000 W
Sample volume required
40-50 mL
Compliance
CE Mark
EMC directive
89/336/EEC
Low voltage directive
73/23/EEC
HI-POT
1900VDC, 60s
Waste Receiver
Specifications
Dimensions (W x D x H)
267 x 305 x 216 mm
Weight
8.2 kg
Julabo® FE500 Recirculating Cooler
Specifications
Dimensions (W x D x H)
305 x 457 x 572 mm
Weight
38.2 kg
Working temperature range
-20 to +40 °C
Display
LED, actual/setpoint
Display resolution
0.1°C
Temperature setting
Keypad
Temperature stability
±0.5°C
Safety
  • audible high/low temperature warning
  • freezing protection
Cooling capability
450 W @ 5°C

Required Accessories

A chiller capable of cooling water to 5°C is required. Supplied with the CCS-2100 is a Julabo FE500 Recirculating Cooler. The CCS requires a computer (not supplied) with the Windows® 98/NT®/XP® operating system.